Question 1: If the red light of miner long on
1. Normal startup, the miner dashboard is not configured, and turns off after configuration.
Solution: Use the group control software to scan the miner IP and enter the dashboard to configure the mining pool address and wallet address. After selecting the corresponding currency mode, it can work normally.
2. The dashboard configuration is incorrect and a valid pool cannot be detected.
Solution: Check whether the mining pool status is "In use", if it is "Dead", change the valid mining pool address
3. Misoperation or power outage midway.
Solution: Check whether the miner is powered on normally and whether the voltage is stable
4. Control board damaged.
Solution:Check to see if the indicator light on the control panel is red
5. Hashboard is damaged
Solution: Enter the log to view
6. Not working at high temperature.
Solution: There is a high temperature warning in the log. The temperature threshold exceeds 70 degrees Celsius and requires physical cooling.
Question 2: If the miner keeps rebooting
1. The DAG file inside the miner is updated 2-3 times a week and will be restarted at that time. This is normal.
Solution: ignore
Notice: Usually the frequency is once a week. If the frequency is too high, please contact after-sales service.
2. Detected that the hashrate is too low
Solution: Check the log or after-sales help
Notice: Contact after-sales service.
3. Pool link is unstable
Solution: Change a mining pool address
Notice: If some mining pool official websites update their addresses, ask customer service for the latest effective address.
4. The network link is unstable
Solution: Check internet speed
5. Voltage is unstable
Solution: Exclude voltage environment
6. high temperature
Solution: Ensure that the indoor temperature is within 25 degrees Celsius, that there are no obstructions in the vents, and that indoor air circulation is normal.
Question 3: If the miner keep low hashrate
1. Based on the 24-hour average hashrate, instantaneous low hashrate is not a reference value.
Solution: Continue observation for at least 24 hours
2. Fluctuation of 10% is normal
Solution: The 10% fluctuation based on the rated model of the miner is normal.
3. The chip itself is defective and the internal circuit is short-circuited.
Solution: Return to factory
4. Lose a chip
Solution: Return to factory
5. The cable is not inserted securely and the contact is insufficient.
Solution: Disassemble the miner and replace the cables
Notice: Before disassembling the miner, you need to take photos and send the SN code of the miner and the torn off non-warranty label.
6. There is a commission on the mining pool side.
Solution: Confirm with the official mining pool
7. high temperature
Solution: Ensure that the indoor temperature is within 25 degrees Celsius, that there are no obstructions in the vents, and that indoor air circulation is normal.
8. Firmware defects
Solution: Update to latest firmware
9. Altercoins
Solution: The currency algorithm is not supported or not fully supported
10. Dual Mining
Solution: The hashrate of dual mining is relatively low
11. The pool does not support
Solution: Replace the pool
12. Algorithm not supported
Solution: Not support
13. DAG file does not have enough memory
Solution: Not support
14. The network link is unstable
Solution: Check network
15. Voltage is unstable
Solution: Check voltage
Question 4: If the hashrate of miner keep 0
1. Pool error
Solution: Replace the pool
2. Network Error
Solution: Check network
3. Network segment IP address change
Solution: Self-check the network segment to see if there are two routers. Group control can be used to manually add network segments.
4. The hashboard is damaged
Solution: Return to factory
5. Wrong mode selected
Solution: Select the mode corresponding to the currency
6. Configuration error
Solution: Reconfigure
Question 5: If the temperature of the miner is too high
1. Fans damaged
Solution: Replace fans
2. The air outlet is blocked
Solution: Check if there is anything blocking the air outlet
3. Cooling tower damaged
Solution: Symptoms of abnormally high temperature and feeling hot to the touch
Notice: Need to cut off the power immediately
4. The cooling tower is loose and misaligned
Solution: Disassemble and inspect, re-fix and apply silicone grease
Notice: Need to cut off the power immediately
5. Improper indoor temperature control
Solution: Ensure that the indoor temperature is within 25 degrees Celsius, that there are no obstructions in the vents, and that indoor air circulation is normal.
6. Hashboard short circuit
Solution: Return to factory
Notice: The indicator light of the hashboard flashes white.
7. Accumulating dust
Solution: Clean up dust regularly
Notice: Once a year in normal environment, wind cleaning is recommended
8. Short circuit
Solution: Return to factory
Question 6: If the miner' DAG loading takes too long
1. Chip reading program error
Solution: Return to factory
2. Pool link is unstable
Solution: Replace the pool
Notice: This is manifested by frequent switching between pools and a high rejection rate.
3. Short circuit inside the chip
Solution: Return to factory
4. chip not working
Solution: Return to factory
5. Individual differences in chips
Solution: Wait for the miner to show hashrate
Notice: Within 40 minutes is usually normal
Question 7: If the power consumption of the miner is too high
1. Power supply damaged
Solution: Replace power supply
Notice: It can be tested by replacing the power supply of other miners.
2. Wrong input voltage connected
Solution: Exclude site voltage range
3. No adapter installed
Solution: Install adapter
Notice: It is recommended to install an adapter in the Americas or other areas with different power ranges.
4. Overclocking mode enabled
Solution: Normal
5. Reader error
Solution: Return to factory or replace parts
Question 8: If the miner keeps dropping out
1. Pool address error
Solution: Replace the pool
2. URL address reading error
Solution: Check whether the pool prefix is written incorrectly
Notice: You can try both tcp and ssl
3. Internet speed is unstable
Solution: Check network
4. The pool is unstable
Solution: Replace the pool
5. Not configured
Solution: Dashboard configuration
6. Chip failure
Solution: Return to factory
7. Wireless network link is unstable
Solution: It is recommended to change to a network cable
Question 9: If the miner fails to boot
1. Power supply damaged
Solution: Replace power supply
2. Power cable
Solution: Replace power cord
3. There is a short circuit between the hashboard and the power supply link.
Solution: Check the wiring port
Question 10: If the miner's red and green lights are always on
1. The miner has no executable firmware
Solution: Card swipe
Question 11: If the ultra mode is not found when the miner is configured
1. The firmware has not been upgraded to the latest version 11.17
Solution: The latest firmware needs to be upgraded after downloading version 11.17 from the official website
Notice: No need to unzip the firmware
2. Upgrade failed
Solution: Click on the upgrade blank space to select the firmware compressed package body, no need to unzip it, and then press Upgrade
Notice: Click the blank space to upgrade. Do not click the "Upgrade" button directly.
3. No refresh
Solution: Clear browser memory, change browser, refresh page
Question 12: If the IP address is not found when the miner is configured
1. Network reasons
Solution: Check network
2. Not in the same network segment
Solution: Check if there are other routers and need to manually add network segment settings
3. The group control network segment range has not been modified.
Solution: Check whether the network segment is from 1-254. If not, manually modify the network segment in the dashboard settings.
4. VPN turned on
Solution: Turn off VPN